IEC 62326-1IEC - 国际电工委员会制造工艺

印制板通用规范 / Generic Specification for Printed Boards

印制板通用技术要求和试验方法的IEC总纲性标准,定义了刚性、柔性和刚挠结合印制板的通用性能指标、质量一致性检验程序及环境适应性要求,与IPC-6012系列相对应但采用IEC标准框架,适用于国际贸易中的PCB产品技术规格确认

国际电工委员会2024/6/20980 次阅读版本:2024178页

标准条款

共 10 条
1.0

Scope

第1页

第1-15行

This part of IEC 62326 specifies test methods for evaluating electrochemical migration (ECM) resistance of printed board materials and finished boards. ECM includes conductive anodic filament (CAF) growth and surface dendritic migration under bias and humidity conditions.

IEC 62326electrochemical migrationCAFdendrite
2.0

Definitions

第1页

第16-35行

Conductive Anodic Filament (CAF): Conductive copper salt filament growing along glass fiber reinforcement under electrical bias and moisture. Surface Dendrite: Metallic dendritic growth on PCB surface between biased conductors. Time-to-Failure (TTF): Duration until insulation resistance drops below threshold.

definitionsCAFdendriteTTFcopper salt
3.0

Test Specimen Design

第2页

第1-22行

Coupon with parallel conductor pattern: 0.25 mm spacing, 25 mm length minimum. For CAF testing: PTH pairs at specified spacing (0.5 mm to 2.0 mm). At least 10 test vehicles per condition. Include both inner layer and surface patterns. Reference coupon for baseline IR measurement.

specimenparallel conductor0.25 mmPTH pairsCAF coupon
4.0

Preconditioning

第2页

第23-40行

Clean specimens with IPA rinse and dry at 105°C for 1 hour. Apply flux if simulating assembly process. Solder reflow simulation if applicable. Store in desiccator before testing. Baseline insulation resistance measured at 100V DC, must exceed 1 GΩ.

preconditioningIPA cleaningbaseline IR1 GΩdesiccator
5.0

Surface ECM Test

第3页

第1-22行

Apply DC bias voltage (typically 10V to 100V) across surface conductors. Test environment: 85°C/85% RH in temperature-humidity chamber. Continuous monitoring of leakage current at intervals ≤ 1 hour. Failure criterion: IR drop below 1 MΩ or 3 orders of magnitude decrease.

surface ECMDC bias85°C/85%RHleakage current1 MΩ
6.0

CAF Resistance Test

第3页

第23-45行

Apply DC bias (typically 50V to 100V) between adjacent PTHs or inner layer conductors. Test conditions: 85°C/85% RH for 1000 hours minimum. Monitor insulation resistance continuously. CAF failure identified by sudden IR drop followed by partial recovery pattern. Cross-section analysis required to confirm CAF.

CAF testPTH bias1000 hoursIR monitoringcross-section
7.0

Data Analysis

第4页

第1-22行

Record time-to-failure for each test vehicle. Calculate median TTF using Weibull or lognormal distribution. Report TTF at 50th percentile (median) and 1st percentile (early failure). Plot IR vs time curves for all specimens. Identify failure mechanism through post-test analysis.

data analysisTTFWeibulllognormalmedianpercentile
8.0

Acceptance Criteria

第4页

第23-40行

Surface ECM: no failures within 1000 hours at rated conditions. CAF resistance: median TTF > 1000 hours at 85°C/85%RH/50V. No early failures (< 100 hours) permitted. Post-test cross-section must show no evidence of filament growth for passing specimens.

acceptanceno failures1000 hoursmedian TTFearly failure
9.0

Failure Analysis

第5页

第1-25行

Cross-section failed specimens through migration path. Polish to reveal filament morphology. SEM/EDS analysis to identify chemical composition of migration product. Document filament growth direction relative to glass fibers. Photograph at multiple magnifications. Determine root cause: material defect, process contamination, or design issue.

failure analysiscross-sectionSEMEDSfilamentroot cause
10.0

Report

第5页

第26-45行

Report shall include: material identification (resin system, glass type, copper foil), specimen geometry and spacing, test conditions (T/RH/bias), preconditioning details, individual TTF values, statistical analysis results, failure analysis findings, comparison to previous lots or baseline data.

reportmaterial IDtest conditionsstatistical analysisbaseline